Cisco Systems MGX 8800 Switch User Manual


 
3-30
Cisco MGX 8800/8900 Series Hardware Installation Guide
Releases 2 - 5.2, Part Number OL-4545-01, Rev. H0, May 2006
Chapter 3 Preparing for Installation
Site Requirements for the MGX 8950 Switch
Vibration
Table 3-9 describes the Cisco recommendations for vibration conditions.
Space
You can install the following MGX 8950 system components in a rack (as shown in Figure 3-6):
Exhaust plenum
Upper fan tray
Cisco MGX 8950 switch
Lower fan tray
Table 3-9 Vibration Condition Recommendations
Category NEBS Description MDVT Description
Earthquake
No damage to the switch when tested
to earthquake waveform.
75-mm maximum single amplitude
deflection.
Frame-level natural mechanical
resonant frequency > 2 Hz.
Frame-level natural mechanical
resonant frequency > 6 Hz.
Product must function before and
after each axis.
Product must operate without loss of
service during earthquake testing.
None
Office
3 axis swept-sine.
5 Hz to 100 Hz to 5 Hz.
0.1 G, 0.1 octaves/min.
0.41 Grms, 3 to 500 Hz
Spectral break points of
0.0005 G
1
/Hz at 10 Hz and 200 Hz
5 dB/octave roll-off at each end
2 hrs per axis of operation
1. Office product—More than 2 m from regularly inhabited positions
Transportation For rail, truck, ship, 5 to 100 Hz,
0.1 octave/min, 0.5 G.
For rail, truck, ship, jet, reciprocating
or turbo prop aircraft, 100 to 500 Hz,
0.25 octave/min, 1.5 G.
3 to 300 Hz, 0.5 G
2
30 min per axis
2
2. Cisco package test specification
Non-Operational None. 1.12 Grms, 3 to 500 Hz
Spectral break points of
0.0065 G
1
/Hz at 10 Hz and 100 Hz
5 dB/octave roll-off at each end
30 minutes in each of 3 axes