Cisco Systems MGX 8800 Switch User Manual


 
B-12
Cisco MGX 8800/8900 Series Hardware Installation Guide
Releases 2 - 5.2, Part Number OL-4545-01, Rev. H0, May 2006
Appendix
Power Cabling
AC Power Cabling—MGX 8850 (PXM1E/PXM45), MGX 8850/B and MGX 8880
We provide a 6-foot (1.8-meter) AC power cord for an AC-powered system. This AC power cord is
available for the following countries:
Argentina: Cisco Part Number CAB-ACR
Australia: Cisco Part Number PWRCD-ANZ
Continental Europe: Cisco Part Number PWRCD-EU
Great Britain: Cisco Part Number PWRCD-GBI
Ireland: Cisco Part Number PWRCD-GBI
Italy: Cisco Part Number PWRCD-IT
Japan: Cisco Part Number PWRCD-NA
New Zealand: Cisco Part Number PWRCD-ANZ
North America: Cisco Part Number PWRCD-NA (NEMA L6-20 twistlock plug)
For the number of power cords that support your MGX 8850 (PXM1E/PXM45), MGX 8850/B and
MGX 8880 switches, see Table 1-5.
AC Power Cabling—MGX 8950
We provide a 10-foot (3 meter) AC power cord for an AC-powered system. This AC power cord is
available for the following countries:
Europe: Cisco Part Number PWRCD-30A-EU
North America: Cisco Part Number PWRCD-30A-NA
Table B-11 shows the power cords requirements for the MGX 8950 switch.
For the number of power cords that support your MGX 8950 switch, see Table 3-14.
AC Power Cabling—MGX 8830 and MGX 8830/B
Either Cisco or the customer can provide the AC power cord. See Table B-12 for the power cords that
Cisco can supply. In addition, you can special-order AC cables with other plugs or different lengths. If
you want to construct the power cord, it must mate with an IEC320 (C-14) 10/15A male receptacle on
the back of the AC power module.
Table B-11 AC Power Cable and Plug Requirements—MGX 8950
Cable Parameter Description
Cable Provided with 10 feet (2.3 m) of 3-conductor wire with plug.
Plug (customer end) 30A NEMA L6-30, 3-prong plug (United States)
For international use, the line cord is hard-wired with an IEC309 plug.