Chapter 4 Parameters|
4-72 Revision Nov. 2008, VLE1, SW V1.03
Bit0 Bit1 Bit2 Bit3 Bit4 Bit5 Bit6
Fault code
current Volt. OL SYS FBK EXI CE
15: Phase loss (PHL)
●
16: IGBT heat sink over-heat (oH1)
●
17: Heat sink over-heat (oH2)(for
40HP above)
●
18: TH1 open loop error (tH1o)
●
19: TH2 open loop error (tH2o)
●
20: Fan error signal output
●
21: over-load (oL) (150% 1Min)
●
22: Motor 1 over-load (EoL1)
●
23: Reserved
24: Motor PTC overheat (oH3)
●
25: Reserved
26: over-torque 1 (ot1)
●
27: over-torque 1 (ot2)
●
28: Reserved
29: Reserved
30: Memory write-in error (cF1)
●
31: Memory read-out error (cF2)
●
32: Isum current detection error (cd0)
●
33: U-phase current detection error
(cd1)
●
34: V-phase current detection error
(cd2)
●
35: W-phase current detection error
(cd3)
●
36: Clamp current detection error
(Hd0)
●
37: Over-current detection error (Hd1)
●
38: Over-voltage detection error (Hd2)
●