Delta Electronics VFD-VL Network Card User Manual


 
Chapter 4 Parameters|
4-14 Revision Nov. 2008, VLE1, SW V1.03
Group 8 PM Motor Parameters
Pr. Explanation Settings
Factory
Setting
VF
VFPG
SVC
FOCPG
TQCPG
FOCPM
08-00
Motor Auto Tuning 0: No function
1: Only for the unloaded motor, auto measure the angle
between magnetic field and PG origin (08-09)
2: For PM motor parameters
3: Auto measure the angle between magnetic field and PG
origin (08-09)
0
08-01 Full-load Current of Motor 40-120% #.##
08-02
Rated power of Motor 0.00~655.35 kW #.##
08-03
Rated speed of Motor (rpm) 0~65535 1710
08-04 Number of Motor Poles 2~96 4
08-05 Rs of Motor
0.000~65.535Ω
0.000
08-06 Ld of Motor 0.0~6553.5mH 0.0
08-07 Lq of Motor 0.0~6553.5mH 0.0
08-08 Reserved
08-09 Angle between Magnetic
Field and PG Origin
0.0-360.0°
360
08-10 Magnetic Field Re-
orientation
0: Disable
1: Enable
0