Delta Electronics VFD-VL Network Card User Manual


 
Chapter 4 Parameters|
4-6 Revision Nov. 2008, VLE1, SW V1.03
Pr. Explanation Settings
Factory
Setting
VF
VFPG
SVC
FOCPG
TQCPG
FOCPM
14: Brake chopper signal 0
15: Motor-controlled magnetic contactor output 0
02-16
Multi-function Output 6
(MO4)
16: Slip error (oSL)
17: Malfunction indication 1
18: Reserved
19: Brake chopper output error
20: Warning output
02-17
Multi-function Output 7
(MO5)
21: Over voltage warning
0
22: Over-current stall prevention warning 0
02-18
Multi-function Output 8
(MO6)
23: Over-voltage stall prevention warning
24: Operation mode indication (Pr.00-15≠0) ○ ○
02-19
Multi-function Output 9
(MO7)
25: Forward command
0
26: Reverse command
02-20
Multi-function Output 10
(MO8)
27: Output when current >= Pr.02-33
0
28: Output when current < Pr.02-33
02-21
Multi-function Output 11
(MO9)
29: Output when frequency >= Pr.02-34
0
30: Output when frequency < Pr.02-34 0
02-22
Multi-function Output 12
(MO10)
31-32: Reserved
33: Zero speed (actual output frequency)
34: Zero speed with Stop (actual output frequency)
35: Fault output option 1 (Pr.06-22)
36: Fault output option 2 (Pr.06-23)
37: Fault output option 3 (Pr.06-24)
38: Fault output option 4 (Pr.06-25)
39: Reserved
40: Speed attained (including zero speed)
41: Reserved
02-23
Multi-output Direction 0 ~ 65535
0
02-24
Serial Start Signal Selection 0: by FWD/REV
1: by Enable
0
02-25
Desired Frequency Attained
1
0.00 ~ 120.00Hz
60.00/
50.00
02-26
The Width of the Desired
Frequency Attained 1
0.00 ~ 120.00Hz
2.00
02-27
Desired Frequency Attained
2
0.00 ~ 120.00Hz
60.00/
50.00
02-28
The Width of the Desired
Frequency Attained 2
0.00 ~ 120.00Hz
2.00
02-29
Brake Release Delay Time
when Elevator Starts
0.000~65.000 Sec
0.250
02-30 Brake Engage Delay Time
when Elevator Stops
0.000~65.000 Sec
0.250
02-31
Turn On Delay of Magnetic
Contactor between Drive
and Motor
0.000~65.000 Sec
0.200
02-32
Turn Off Delay of Magnetic
Contactor between Drive
and Motor
0.000~65.000 Sec
0.200
02-33
Output Current Level Setting
for External Terminals
0~100%
0
02-34
Output Boundary for
External Terminals
0.00~+-120.00Hz (it is motor speed when using with PG)
0.00
02-35
Detection Time of
Mechanical Brake
0.00~10.00 Sec
0.00