Delta Electronics VFD-VL Network Card User Manual


 
Chapter 3 Operation and Start Up|
3-2 Revision Nov. 2008, VLE1, SW V1.03
Operation Method Frequency Source
Operation
Command Source
Operate from
communication
Please refer to the communication address 2000H and 2119H settings
in the communication address definition.
Control Terminals-
Operate from
external signal
REV
MI1
MI2
MI3
MI4
MI6
MI5
FWD
MI7
E
NOTE
MI8
COM
+10V
-10V
AUI1/AUI2
E
ACI
ACM
4~20mA
A
*
Factory setting:
SINK Mode
multifunction
terminals
Factory
setting
Forward/STOP
Multi-step 1
Multi-step 2
Multi-step 3
Multi-step 4
No function
Digital Signal Common
No function
No function
No function
* Don't apply the mains voltage directly
to above terminals.
Power supply-10V 20mA
Master Frequency
-10 to 10V
Reverse/STOP
(*1)
(*1)
(*1) When JP1
on the co ntrol bo ard is inserted, MI8 is disabled.
KPVL-CC01
keypad
(Optional)
UP/DOWN key
RUN,
STOP/RESET
key