Delta Electronics VFD-VL Network Card User Manual


 
Chapter 4 Parameters|
4-12 Revision Nov. 2008, VLE1, SW V1.03
Pr. Explanation Settings
Factory
Setting
VF
VFPG
SVC
FOCPG
TQCPG
FOCPM
11: Low-voltage during acceleration (LvA)
12: Low-voltage during deceleration (Lvd)
13: Low-voltage during constant speed (Lvn)
14: Low-voltage at stop (LvS)
15: Phase loss (PHL)
16: IGBT heat sink over-heat (oH1)
17: Heat sink over-heat (oH2)(for 40HP above)
18: TH1 open loop error (tH1o)
19: TH2 open loop error (tH2o)
20: Fan error signal output
21: over-load (oL) (150% 1Min)
22: Motor over-load (EoL1)
23: Reserved
24: Motor PTC overheat (oH3)
25: Reserved
26: over-torque 1 (ot1)
27: over-torque 1 (ot2)
28: Reserved
29: Reserved
30: Memory write-in error (cF1)
31: Memory read-out error (cF2)
32: Isum current detection error (cd0)
33: U-phase current detection error (cd1)
34: V-phase current detection error (cd2)
35: W-phase current detection error (cd3)
36: Clamp current detection error (Hd0)
37: Over-current detection error (Hd1)
38: Over-voltage detection error (Hd2)
39: Ground current detection error (Hd3)
40: Auto tuning error (AuE)
41: PID feedback loss (AFE)
42: PG feedback error (PGF1)
43: PG feedback loss (PGF2)
44: PG feedback stall (PGF3)
45: PG slip error (PGF4)
46: PG ref input error (PGr1)
47: PG ref loss (PGr2)
48: Analog current input error (ACE)
49: External fault input (EF)
50: Emergency stop (EF1)
51: Reserved
52: Password error (PcodE)
53: Reserved
54: Communication error (cE1)
55: Communication error (cE2)
56: Communication error (cE3)
57: Communication error (cE4)
58: Communication Time-out (cE10)
59: PU time-out (cP10)
60: Brake chopper error (bF)
61-62: Reserved
63: Safety loop error (Sry)
64: Mechanical brake error (MBF)
65: PGF5 hardware error
06-22
Fault Output Option 1 0~65535 (refer to bit table for fault code) 0
○ ○
06-23
Fault Output Option 2 0~65535 (refer to bit table for fault code) 0
○ ○
06-24
Fault Output Option 3 0~65535 (refer to bit table for fault code) 0
○ ○
06-25
Fault Output Option 4 0~65535 (refer to bit table for fault code) 0
○ ○
06-26
PTC (Positive Temperature
Coefficient) Detection
Selection
0: Warn and keep operation
1: Warn and ramp to stop
0
○ ○
06-27
PTC Level 0.0~100.0% 50.0
○ ○
06-28
Filter Time for PTC
Detection
0.00~10.00sec 0.20
○ ○
06-29 EPS Voltage
48.0~375.0Vdc
96.0~750.0Vdc
48.0
96.0
○ ○
06-30
Setting Method of Fault
Output
0: By settings of Pr.06-22~06-25
1: By the binary setting
0
○ ○