Delta Electronics VFD-VL Network Card User Manual


 
Chapter 4 Parameters|
Revision Nov. 2008, VLE1, SW V1.03 4-105
P
I
Hz
10-15
10-16
10-13
10-14
10-11
10-12
0Hz
10-17
10-20
10-21
P
I
Hz
11-08
11-07
0Hz
10-17
PI adjustment-manual gain
PI adjustment-auto gain
Pr.11-06
use to adjust the
strength of zero-
servo lock
10-20
10-21
11-01 Elevator Speed Unit: 0.01
Control
mode
FOCPG FOCPM
Factory Setting: 1.00
Settings 0.10 to 3.00 m/s
11-02 Sheave Diameter Unit: 1
Control
mode
FOCPG FOCPM
Factory Setting: 400
Settings 100 to 2000 mm
11-03 Mechanical Gear Ratio Unit: 1
Control
mode
FOCPG FOCPM
Factory Setting: 1
Settings 1 to 100
11-04 Suspension Ratio Unit: 1
Control
mode
FOCPG FOCPM
Factory Setting: 1
Settings 0 1:1
1 2:1