Delta Electronics VFD-VL Network Card User Manual


 
Chapter 4 Parameters|
Revision Nov. 2008, VLE1, SW V1.03 4-101
10-12 ASR (Auto Speed Regulation) Control (I) of Zero Speed Unit: 0.001
Control
mode
VF VFPG SVC FOCPG FOCPM
Factory Setting: 0.100
Settings 0.000 to 10.000 sec
10-13 ASR (Auto Speed Regulation) control (P) 1 Unit: 0.1
Control
mode
VF VFPG SVC FOCPG FOCPM
Factory Setting: 100.0
Settings 0.0 to 500.0%
10-14 ASR (Auto Speed Regulation) control (I) 1 Unit: 0.001
Control
mode
VF VFPG SVC FOCPG FOCPM
Factory Setting: 0.100
Settings 0.000 to 10.000 sec
10-15 ASR (Auto Speed Regulation) control (P) 2 Unit: 0.1
Control
mode
VF VFPG SVC FOCPG FOCPM
Factory Setting: 100.0
Settings 0.0 to 500.0%
10-16 ASR (Auto Speed Regulation) control (I) 2 Unit: 0.001
Control
mode
VF VFPG SVC FOCPG FOCPM
Factory Setting: 0.100
Settings 0.000 to 10.000 sec
10-17 ASR 1/ASR2 Switch Frequency Unit: 0.01
Control
mode
VF VFPG SVC FOCPG FOCPM
Factory Setting: 7.00
Settings 0.00 o 120.00Hz
0.00: disable
ASR P determines Proportional control and associated gain (P). ASR I determines integral
control and associated gain (I).
When integral time is set to 0, it is disabled. Pr.10-17 defines the switch frequency for the
ASR1 (Pr.10-13, Pr.10-14) and ASR2 (Pr.10-15, Pr.10-16).
10-17
10-13
10-14
10-15
10-16
Hz
P
I
10-11
10-12
0Hz
10-20
10-21