Chapter 6 Managing BCM50 with SNMP 137
BCM50 Administration Guide
5 Configure SNMP settings.
The following combinations of SNMP versions are allowed:
Option 1: SNMP v1, SNMP v2 and SNMP v3.
Option 2: SNMP v3 only. This option provides more stringent security protection than
option 1 does.
Option 3: SNMP v2 and SNMP v1.
6 Click the OK button.
Adding an SNMP manager to the BCM50 SNMP manager list
To add an SNMP manager to the BCM50 SNMP manager list
1 Click the Configuration tab.
2 Open the Administrator Access folder, and then click SNMP.
3 Click the General tab.
The General panel is displayed.
4 In the SNMP Manager List area, click the Add button.
The Add Manager dialog box opens.
Table 39 Configure SNMP Settings Attributes
Attribute Action
Enable SNMP Agent Select whether to enable or disable the SNMP agent by selecting the check
box.
Minimum Required Security Select the minimum required security for SNMP. Options are: AuthNoPriv
or NoAuthNoPriv. Valid for SNMP v3.
SNMP Version Support Select the appropriate version from the drop-down list.
Note: If you configure an SNMP manager with an IP address of 0.0.0.0, the
SNMP agent will respond to SNMP queries from all stations.
Caution: If you add more than five SNMP management stations, the SNMP
service may degrade system performance.