Nortel Networks BCM50 2.0 Webcam User Manual


 
166 Chapter 7 Using the BCM Fault Management System
NN40020-600NN40020-600
54 334 minor Core
Telephony
Core Telephony -
"Alarm Indication"
short term alarm
threshold has been
exceeded on the
DTM. The module is
in a no-new-calls
state.
Check your cabling
from any DTM
modules to the
external network and
run loopback tests
on the circuit to
check for network
issues. If long term
alarms occur get
your network
provider to check the
circuit during
problem conditions.
Yes No No No
55 335 minor Core
Telephony
Core Telephony -
"Remote Alarm
Indication" short
term alarm
threshold has been
exceeded on the
DTM. The module is
in a no-new-calls
state.
Check your cabling
from any DTM
modules to the
external network and
run loopback tests
on the circuit to
check for network
issues. If long term
alarms occur get
your network
provider to check the
circuit during
problem conditions.
Yes No No No
56 336 information Core
Telephony
Core Telephony -
The Digital Trunk
T1/E1/PRI has
recovered.
No Action Required. Yes No No No
57 367 minor Core
Telephony
Core Telephony -
Digital Trunk Media
bay module reset.
Determine whether
this alarm occurred
due to the system
rebooting. If the
system was not
rebooting when the
alarm occurred, then
contact your local
support group.
Yes No No No
58 372 warning Core
Telephony
Core Telephony -
Clocking on the
Digital Trunk Media
bay module has
changed sources.
No Action Required. Yes No No No
59 401 minor Core
Telephony
Core Telephony -
Digital station loop
initialization error.
Verify that all types
of attached sets/
peripherals initialize
and function. If
something is not
working reset it. If
the problem persists
contact your local
support group.
Yes No No No
60 608 minor Core
Telephony
Core Telephony -
Unsupported set/
peripheral
connected.
Verify that all types
of attached sets/
peripherals initialize
and function.
Remove any
unsupported set
types.
Yes No No No