Nortel Networks BCM50 2.0 Webcam User Manual


 
Chapter 7 Using the BCM Fault Management System 191
BCM50 Administration Guide
282 11203 minor Platform
Status
Monitor
Platform Status
Monitor - CPU load
above threshold.
Use BCM Monitor
for real-time view of
CPU activity.
Monitor for alarm
11005 to indicate
CPU recovered. If
problem persists,
contact local support
group.
Yes No No No
283 11204 major Platform
Status
Monitor
Platform Status
Monitor - 1. rx_byte/
sec greater than
50% of LAN%#%
speed,
2. tx_byte/sec
greater than 50% of
LAN%#% speed,
3. rx_errors/sec of
LAN%#% > %#%,
4. tx_errors/sec of
LAN%#% > %#%,
5. rx_dropped/sec of
LAN%#% > %#%,
6. tx_dropped/sec of
LAN%#% > %#%
Verify that Customer
LAN is performing
as expected.
Yes Yes Yes Yes
284 11209 major Platform
Status
Monitor
Platform Status
Monitor - Failed to
read Local
Temperature.
Reboot system and
if problem reoccurs
contact your local
support group.
Yes Yes Yes Yes
285 11210 major Platform
Status
Monitor
Platform Status
Monitor - Failed to
read Remote
Temperature.
Reboot system and
if problem reoccurs
contact your local
support group.
Yes Yes Yes Yes
286 11212 major Platform
Status
Monitor
Platform Status
Monitor - Fan Below
Tolerance.
Check Fan operation
as fan is apparently
not working
correctly. If alarm
persists, replace fan.
Yes Yes Yes Yes
287 11213 major Platform
Status
Monitor
Platform Status
Monitor - Failed to
get Router status.
Check the router
and if needed
replace it.
Yes Yes Yes Yes
288 11214 warning Platform
Status
Monitor
Platform Status
Monitor - OAM Port
Link Down.
Check the OAM Port
physical LAN
connection
Yes No No No
289 11215 warning Platform
Status
Monitor
Platform Status
Monitor - Customer
LAN Port 1 Link
Down.
Check the Customer
LAN Port 1 physical
LAN connection
Yes No No No
290 11216 warning Platform
Status
Monitor
Platform Status
Monitor - Customer
LAN Port 2 Link
Down.
Check the Customer
LAN Port 2 physical
LAN connection
Yes No No No
291 11217 warning Platform
Status
Monitor
Platform Status
Monitor - Customer
LAN Port 3 Link
Down.
Check the Customer
LAN Port 3 physical
LAN connection
Yes No No No
292 11250 major Platform
Status
Monitor
Platform Status
Monitor - The size of
XXX Log file is
greater than 16MB,
XXX Log file will be
deleted to recover /
var/log partition.
Contact your local
support group.
Yes Yes Yes Yes