Q-Logic FC Network Card User Manual


 
3–Interactive Commands
Diagnostics Menu (Command Line Options -kl, -kr, and -dm)
3-76 SN0054614-00 K
2: Disk
Vendor : SEAGATE
Product ID : ST118273 CLAR18
Port Name : 21-00-00-20-37-11-FF-EF
Port ID : 11-01-E8
Beacon : No
3: Beacon Selected Target(s)
4: Return to Previous Menu
You can select a disk number to blink the LED on that target. The blinking asterisk
(
*) below the Device Port Name line shows that the target beacon is active.
------------------------------------------------------------------------------
HBA Instance 1: 2200 Port 2 WWPN 21-01-00-E0-8B-23-55-7C PortID 11-06-00
------------------------------------------------------------------------------
Target Beacon
--------------------------------------------------
Hit <RETURN> to abort
--------------------------------------------------
Device Port Name Beacon Status
------------------------ -------------
21-00-00-20-37-11-FF-EF On - Active
*
Beacon Selected Target(s)
11: Beacon 2: Locate Target(s) 3: Beacon Selected Target(s)
When you select the Beacon Selected Target(s) option, SANsurfer FC/CNA
HBA CLI shows a list of the targets associated with the adapter. You can select
any target to toggle the Beacon LED for that target:
Diagnostics Menu
(Command Line Options -kl, -kr, and -dm)
12: Diagnostics
The Diagnostics menu provides end-to-end diagnostics that allow you to test the
adapters and the devices to which they are connected. The SANsurfer FC/CNA
HBA CLI diagnostics include the following:
Loopback test, which is external to the adapter, evaluates the ports (transmit
and receive transceivers) on the adapter and the error rate.
Read/write buffer test verifies the link between the adapter and its attached
devices.