Q-Logic FC Network Card User Manual


 
3–Interactive Commands
Diagnostics Menu (Command Line Options -kl, -kr, and -dm)
3-80 SN0054614-00 K
Data Size (Bytes) : 512
Number of test(s)(1-65535) : 65535
Test Increment(1-65535) : 1
On Error : Ignore
Test Continuous : OFF
Loopback Type : External Loopback
------------------------------------------------------------------------------
Reset Test Parameters (Loopback)
12: Diagnostics n: Port Number 1: Loopback Test2: Reset Test Parameters
Select this option to reset the current loopback test parameters to the defaults.
The default settings are restored immediately.
Restoring default settings ..., done.
Configure Test Parameters (Loopback)
12: Diagnostics n: Port Number 1: Loopback Test3: Configure Test Parameters
Select the Configure Test Parameters option to set the parameters for the
loopback test. For example:
Diagnostic Menu (Loopback)
HBA Instance 2 (QLE2562 Port 1) : Online
WWPN: 21-00-00-1B-32-1B-4E-4C
Desc: QLE2562 PCI Express to 8Gb FC Dual Channel
1: Data Pattern
2: Data Size
3: Number of Test(s)
4: Test Increment(s)
5: On Error Policy
6: Enable/Disable Test Continuously
7: Loopback Type
(displayed for 8Gb adapters only)
8: Return to Previous Menu
Table 3-10 shows the diagnostics configuration settings.