Q-Logic FC Network Card User Manual


 
3–Interactive Commands
Diagnostics Menu (Command Line Options -kl, -kr, and -dm)
3-86 SN0054614-00 K
Transceiver Details: General
Select the General option on the Transceiver Details menu to view general
information for the selected adapter port. The following shows an example:
------------------------------------------------------------------------------
HBA Instance 0: QLE8142 Port 1 WWPN 21-00-00-C0-DD-12-0D-ED PortID C5-02-20
------------------------------------------------------------------------------
------------------------------------------------------------------------------
Media Information
------------------------------------------------------------------------------
Vendor: FINISAR CORP.
Type: 10G Base-SR
Part Number: FTLX8572D3BCL
Speed: 10 GBytes/Sec
Revision: A
Serial Number: UDL0019
QLogic SFP Installed: Yes
------------------------------------------------------------------------------
Temperature Voltage Tx Bias Tx Power Rx Power
(C) (V) (mA) (mW) (mW)
-------------- ------- ------- -------- --------
Value 35.84 3.33 8.04 0.5835 0.6172
Status Normal Normal Normal Normal Normal
High Alarm 78.00 3.70 11.80 0.8318 1.0000
High Warning 73.00 3.60 10.80 0.7079 0.7943
Low Warning -239.00 3.00 5.00 0.3162 0.0158
Low Alarm -244.00 2.90 4.00 0.2512 0.0100
Transceiver Details: Details
Select the Details option on the Transceiver Details menu to view detailed
information for the selected adapter port. The following shows an example:
------------------------------------------------------------------------------
HBA Instance 0: QLE8142 Port 1 WWPN 21-00-00-C0-DD-12-0D-ED PortID C5-02-20
------------------------------------------------------------------------------
Optical Transceiver Digital Diagnostic Data:
NOTE:
The diagnostic transceiver details (DMI) are not available for the QLE8042
FCoE engine.