Q-Logic FC Network Card User Manual


 
4–Non-Interactive Commands
Command Summary
4-6 SN0054614-00 K
You cannot combine the command -f with any other options:
-f = Input Parameter Options from a Text File (see “-f (Input Parameter
Options from a Text File)” on page 4-13). For example:
# scli -f command.txt
In addition, the following general rules for commands apply:
Only one command line option per input file is valid.
You can use either the hyphen (-) character or the forward slash (/)
character. For example, both of these commands are valid:
scli -g
scli /g
Table 4-2 defines the command variables.
.
-a
(View or Toggle Beacon Status)
Use the -a command to either view (1) or change (2) the status of a beacon.
Table 4-2. Command Variables
Variable Definition Format
<hba instance>
Adapter number
a
a
You can use the -g command to find adapter numbers.
<hba wwpn> Adapter world wide port
name
xx-xx-xx-xx-xx-xx-xx-xx or
xxxxxxxxxxxxxx
<alias> Adapter alias
Symbolic adapter
b
name
b
You assign the symbolic name. It is limited to 100 characters in length.
<target wwnn> Target world wide node
name
xx-xx-xx-xx-xx-xx-xx-xx or
xxxxxxxxxxxxxx
<target wwpn> Target world wide port
name
xx-xx-xx-xx-xx-xx-xx-xx or
xxxxxxxxxxxxxx
<target port id> Target port ID xx-xx-xx or xxxxxx
<target id> Target ID
<lun id> Logical unit number (0–255)
<address> IP address xxx.xxx.xxx.xxx
(speed) Target link speed 1.2 or 4 GHz, or 8G
Table Notes