Q-Logic FC Network Card User Manual


 
4–Non-Interactive Commands
Command Summary
4-28 SN0054614-00 K
Where:
Sections “DataPattern (DP)” on page 4-21 through “OnError (OE)” on page 4-24
describe how to change the default parameters for both of these tests. “Run a
Loopback Test” on page 4-24 contains command line examples and test results
for a loopback test. “Run a Read/Write Buffer Test” on page 4-28 contains
command line examples and test results for a read/write buffer test.
Run a Read/Write Buffer Test
This test runs on all devices or on the devices you select on the adapter you
select. This test sends the SCSI Write Buffer command to the target devices and
uses the SCSI Read Buffer command to read the returned data and do a data
comparison.
hba instance = Adapter number (use -g command to find)
hba wwpn = World wide port name of the adapter
-ex or -exclude = World wide port name of the target device that is
excluded from the read/write test
param name = One of the following:
DataPattern (see “DataPattern (DP)” on page 4-21)
DataSize (see “DataSize (DS)” on page 4-23)
TestCount (see “TestCount (TC)” on page 4-23)
TestIncrement (see “TestIncrement (TI)” on
page 4-23)
OnError (see “OnError (OE)” on page 4-24)
param alias = One of the following:
DP (see “DataPattern (DP)” on page 4-21)
DS (see “DataSize (DS)” on page 4-23)
TC (see “TestCount (TC)” on page 4-23)
TI (see “TestIncrement (TI)” on page 4-23)
OE (see “OnError (OE)” on page 4-24)
param value = Value for selected parameter
NOTE:
All devices attached to the adapter must support SCSI Read/Write Buffer
commands.