Q-Logic FC Network Card User Manual


 
3–Interactive Commands
Diagnostics Menu (Command Line Options -kl, -kr, and -dm)
SN0054614-00 K 3-85
operations. Please make sure there is no active I/O before starting
the test(s).
Do you want to proceed with the test(s)?
1. Yes
2. No
Type 1 to proceed or 2 to cancel the operation. If you proceed, the test runs as
shown in the following example:
--------------------------------------------------------------------------------
HBA Instance 8: QLE8142 Port 1 WWPN 21-00-00-C0-DD-0A-B1-FD PortID C5-02-0D
--------------------------------------------------------------------------------
------------------
Test Configuration
------------------
Data Pattern : Random
Data Size (Bytes) : 128
Number of test(s)(1-10000) : 10000
Test Increment(1-10000) : 1
On Error : Ignore
Test Continuous : OFF
------------------------------------------------------------------------
Diagnostics - Read/Write Buffer Test Result
------------------------------------------------------------
Hit <ENTER> to abort
---------------------------------------------
Iter No Data Pattern Status
------- ----------------------- ---------------------------
7219 F8-B8-7D-52-D1-0B-28-A2 Success
7220 - Error: Data mis-compare (C5-01-00 - 1)
Expected Data: 37-1C-6C-B0-B9-CE-EE-A2
Received Data: 00-00-00-F0-00-00-00-00
9999 A6-EE-1C-B0-04-8A-65-BF Success
Diagnostics Transceiver Details: DMI
(Command Line Option -dm)
12: Diagnostics n: Port Number 3: Transceiver Details
The Transceiver Details option is shown only for 4Gb and 8Gb. When you select
this option, SANsurfer FC/CNA HBA CLI shows the Transceiver Details Menu
containing the following options:
General
Details
Select either General or Details, and then press
ENTER
to retrieve the
transceiver information for this port instance.