Q-Logic FC Network Card User Manual


 
3–Interactive Commands
Diagnostics Menu (Command Line Options -kl, -kr, and -dm)
SN0054614-00 K 3-81
Table 3-10. Adapter Diagnostics Configuration Settings
Parameter Name
<param name>
Alias
<param
alias>
Value <param value> Description
DataPattern DP 00–FF
CRPAT
CSPAT
CJTPAT
See table note 1
Loopback test only
Loopback test only
Loopback test only
DataSize DS 8, 16, 32, 64, 128, 256,
512, 1024, 2048
See table note 2
TestCount TC 0–65535 (Loopback)
0–10000 (R/W Buffer)
See table note 3
See table note 3
TestIncrement TI 1–65535 (Loopback)
1–10000 (R/W Buffer)
See table note 4
See table note 4
OnError OE 0, 1, 2 See table note 5
LoopbackType LT 0, 1, 2 See table note 6
Table Notes:
1. DataPattern is the test pattern in hexadecimal format, user-defined pattern (hex), or random pat-
tern.
Hex Binary
00 00000000
55 01010101
5A 01011010
A5 10100101
AA 10101010
FF 11111111
2. DataSize specifies the data (frame payload) size in bytes. Actual data that is transferred during
any given pass of the test. For R/W buffer test, the maximum data size is 128 bytes.
3. TestCount:
0: Test continuously
1–Max: Total number of tests that will be executed
4. TestIncrement must be less than the number of test count specified.
5. OnError specifies the action if an error occurs during any given pass.
0: Ignore
1: Stop
2: Ignore
6. LoopbackType (for 8Gb adapters only):
0: 10 bit internal loopback test
1:
1 bit serial loopback test
2: External loopback test