CHAPTER 13
Removing Switch Components
Removing an AC Power Supply from an EX8200 Switch on page 207
Removing a DC Power Supply from an EX8200 Switch on page 209
Removing a Fan Tray from an EX8208 Switch on page 211
Taking the SRE Module Offline in an EX8208 Switch on page 213
Removing an SRE Module from an EX8208 Switch on page 215
Taking the SF Module Offline in an EX8208 Switch on page 216
Removing an SF Module from an EX8208 Switch on page 217
Removing a Line Card from an EX8200 Switch on page 218
Disconnecting a Fiber-Optic Cable from an EX Series Switch on page 221
Removing a Transceiver from an EX Series Switch on page 222
RemovingthePowerCordTrayfromaRackorCabinetforanEX8200Switchonpage224
Removing an AC Power Supply from an EX8200 Switch
The AC power supply in an EX8200 switch is a hot-removable and hot-insertable
field-replaceableunit(FRU).YouremoveACpowersuppliesfromthefrontofthechassis.
CAUTION: Before you remove a power supply, ensure that youhave powersupplies
sufficientto power theswitchleftinthe chassis.See “CalculatingPower Requirements
for an EX8208 Switch” on page 114 or Calculating Power Requirements for an EX8216
Switch.
Before you remove an AC power supply from the switch:
Ensure you understand how to prevent ESD damage. See “Prevention of Electrostatic
Discharge Damage on EX Series Switches” on page 292.
Ensure that you have the following parts and tools available to remove an AC power
supply from an EX8200 switch chassis:
Electrostatic discharge (ESD) grounding strap
Phillips (+) screwdriver, number 1
207Copyright ©2010,Juniper Networks,Inc.