Juniper Networks EX8208 Switch User Manual


 
8. Place the SF module in the antistatic bag or on the antistatic mat.
9. If you are not replacing the SF module, install the cover panel over the empty slot
by tightening the screws on each side of the cover panel with the screwdriver.
Figure 86: Removing an SF Module from an EX8208 Switch
Related Topics Installing an SF Module in an EX8208 Switch on page 157
Switch Fabric (SF) Module in an EX8208 Switch on page 28
Removing a Line Card from an EX8200 Switch
EX8200 switches have field-replaceable unit (FRU) line cards that can be installed in
the line card slots on the front of the switch chassis. The line cards are hot-insertable
and hot-removable: Youcan remove and replace them without powering off the switch
or disrupting switch functions.
Before you begin removing a line card from an EX8200 switch:
EnsurethatyouhavetakenthenecessaryprecautionstopreventElectrostaticdischarge
(ESD) damage (see “Prevention of Electrostatic Discharge Damage on EX Series
Switches” on page 292).
If there are any transceivers installed in the line card, remove them before you remove
the line card. See “Removing a Transceiver from an EX Series Switch” on page 222.
Ensurethatyouknowhowtohandleand storetheline card(see“Handling andStoring
Line Cards in EX8200 Switches” on page 227).
Copyright ©2010,Juniper Networks,Inc.218
CompleteHardwareGuide forEX8208 EthernetSwitches