Figure 81: Removing an AC Power Supply from an EX8200 Switch
Related Topics Installing an AC Power Supply in an EX8200 Switch on page 150•
• AC Power Supply in an EX8200 Switch on page 40
Removing a DC Power Supply from an EX8200 Switch
The DC power supply in an EX8200 switch is a hot-removable and hot-insertable
field-replaceableunit(FRU).YouremoveDCpowersuppliesfromthefrontofthechassis.
NOTE: EX8208 switches support 2000 W DC power supplies.
EX8216 switches support 3000 W DC power supplies.
CAUTION: Before you remove a power supply, ensure that youhave powersupplies
sufficientto power theswitchleftinthe chassis.See “CalculatingPower Requirements
foranEX8208Switch”on page114andCalculatingPowerRequirementsforanEX8216
Switch.
Before you remove a DC power supply from the switch:
•
Ensure that you understand how to prevent ESD damage. See “Prevention of
Electrostatic Discharge Damage on EX Series Switches” on page 292.
EnsurethatyouhavethefollowingpartsandtoolsavailabletoremoveaDCpowersupply
from an EX8200 switch chassis:
•
Electrostatic discharge (ESD) grounding strap
•
Phillips (+) screwdriver, number 1
209Copyright©2010,Juniper Networks, Inc.
Chapter13: RemovingSwitchComponents