Juniper Networks EX8208 Switch User Manual


 
Table 7: LCD Panel Menu Options for the EX8200 Switch (continued)
DescriptionMenu
TheStatus menu hasthe following options:
Switchfabric status—Choose one of the following:
Press Enterto displaythe statusof the switchfabricin the SRE modules(SRE0 and SRE1) in EX8208
switches and the SF modules(SF) in EX8216 switches:OK, Fld(failed), ABS (absent)
Press Menu togo tothe nextoption in the Statusmenu.
Powersupplystatus(1)—Choose one of the following:
Press Enterto displaythe statusof power supplies 0 and 1: OK, Fld, ABS.
Press Menu togo tothe nextoption in the Statusmenu.
Powersupplystatus(2)—Choose one of the following:
Press Enterto displaythe statusof power supplies 2, 3, 4,and 5: OK, Fld,ABS.
Press Menu togo tothe nextoption in the Statusmenu.
Environmentstatus—Choose one of the following:
Press Enterto displaythe statusof the fantray(s)and the chassistemperature:
Fantray(s)status:OK, Fld, ABS
Chassistemperaturestatus:OK, High, Shutdown
Press Menu togo tothe nextoption in the Statusmenu.
Junos version status—Chooseone of the following:
Press Enterto displaythe versionof Junos OSfor EX Seriesswitchesloadedon the switch.
Press Menu togo tothe nextoption in the Statusmenu.
EXIT STAT MENU?—Choose one of the following:
Press Enterto exitthe Statusmenu.
Press Menu toreturn tothe Switch fabricstatusoption.
If youdo not want usersto use Status menu options, disable the entire menu or individualmenu options. See
Configuringthe LCD Panelon EX SeriesSwitches (CLIProcedure).
Status
Copyright ©2010,Juniper Networks,Inc.20