Juniper Networks EX8208 Switch User Manual


 
Table 21: N+N Power Supply Requirements for EX8208 Switch
Configurations Using 2000 W AC PowerSupplies (JunosOSRelease 10.2
or Later Only)
PowerSupplies
Neededfor N+N
PowerSupplies
Needed(N)Input Voltage
Switch
Configuration
21High-voltage line
(200–240 VAC)
Base
21Low-voltageline
(100–120VAC)
63High-voltage line
(200–240 VAC)
Fullyloaded with
8-port SFP+ line
cards
Not Supported4Low-voltage line
(100–120VAC)
Table 22: N+N Power Supply Requirements for EX8208 Switch
Configurations Using 3000 W AC PowerSupplies(Junos OSRelease 10.2
or Later Only)
PowerSupplies
Neededfor N+N
PowerSupplies
Needed(N)Input Voltage
Switch
Configuration
21High-voltage line
(200–240 VAC)
Base
42High-voltage line
(200–240 VAC)
Fullyloaded with
8-port SFP+ line
cards
Table 23: N+N Power Supply Requirements for EX8216 Switch
Configurations Using 2000 W AC PowerSupplies (JunosOSRelease 10.2
or Later Only)
PowerSupplies
Neededfor N+N
PowerSupplies
Needed(N)Input Voltage
Switch
Configuration
21High-voltage line
(200–240 VAC)
Base
42Low-voltage line
(100–120VAC)
Not supported5High-voltage line
(200–240 VAC)
Fullyloaded with
8-port SFP+ line
cards
Not supportedNot supportedLow-voltageline
(100–120VAC)
45Copyright©2010,Juniper Networks,Inc.
Chapter2:ComponentDescriptions