Upgrading R5si/R6si to R8r EPN and Adding Memory
3-43Release 5/6si to Release 8r
3
4. Behind switch node carrier D of PPN cabinet 1:
a. For each EPN, install 1 lightwave transceiver on a cable connector
with the following order of slots: 1E20, 1E03, 1E19, 1E04, 1E18,
1E05, and so forth.
b. Connect 1 end of each fiber optic cable to each lightwave
transceiver, just installed.
c. Carefully attach the fiber optic cables (with cable ties) to the wall of
the cable tray at the built-in cable tie positions.
5. Behind port cabinet B of each single-carrier EPN:
a. Install a lightwave transceiver on cable connector at slot B02.
NOTE:
Attenuators may be required for single mode fiber using a
300A Lightwave Transceiver
b. Connect the other end of the fiber optic cable to the lightwave
transceiver, just installed, at slot B02.
c. Carefully attach the fiber optic cable (with cable ties) to the rear
covers of the EPN stack.
d. Coil up the surplus length of fiber optic cable, and place the coil
either in the cable manager or on the bottom shelf (holding the
power supply) of the PPN cabinet.