Adding or Removing Cabinet Hardware
6-52Add IP Interface Assembly
6
2. Insert the TN802B IP Interface into the right most of the three slots you
reserved for it (see Figure 6-23
) and seat it properly.
When you plug in the TN802B IP Interface Assembly, the circuit pack
starts to boot and the LCD reads
PC Boot
. The circuit pack reboots
automatically, and after about 3 to 4 minutes the LCD changes to
IPTRK*
,
the default mode, or
MEDPRO*
.
If the TN802B is pre-administered at the factory, it reboots several times to
initialize to MedPro mode.
If the TN802B is not pre-administered, go to
‘‘Administration Steps’’ on
page 6-53
NOTE:
For an initial installation, the TN802B IP Interface needs to be
administered first (see
‘‘Administer the IP Interface’’ on page 6-53
).