Lucent Technologies 555-233-115 Server User Manual


 
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
G3vs with Intel 386 or Risc Processor to R8r
4-19DEFINITY AUDIX Power Procedures
4
DEFINITY AUDIX Power Procedures
Power Down the AUDIX System
A yellow caution sticker on the system’s power unit notifies technicians to shut
down the DEFINITY AUDIX System prior to powering down the system.
1. Log into the AUDIX System as
craft
.
2. Type
reset system shutdown
. Press
Enter
once
.
NOTE:
Do not press Enter again. This will force the AUDIX to shutdown
immediately, dropping all active calls on the AUDIX.
3. The “SHUTDOWN Completed” message appears when the AUDIX is
successfully shutdown. This takes about 2 minutes.
4. The AUDIX System can now be removed for service.
Power Up the AUDIX System
If the AUDIX was removed from the cabinet:
1. Re-install the AUDIX and allow it to boot up automatically.
2. Check for AUDIX System errors.
If the AUDIX remained in the cabinet but power was removed from the
cabinet:
1. Power up the cabinet. The AUDIX reboots automatically.
2. Check for AUDIX System errors.
If the AUDIX remained in the cabinet and the cabinet was
not
powered
down:
1. At the AUDIX console, hold the
crtl key and type
cc
.
2. Type
5
at the prompt. In about 2 minutes, the AUDIX boots up.
3. When the system initialization is complete, log in as
craft
.
4. Check for AUDIX System errors.