Lucent Technologies 555-233-115 Server User Manual


 
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Upgrading G3rV2, V3, V4 to R8r and Adding Memory
1-20Upgrade the software and hardware
1
4. Type the day of month (1 through 31) in the
Day of the Month:
field
and press
Tab to move to the next field.
5. Type the current year in the
Year:
field and press
TA B to move to the next
field.
6. Type the current hour for a 24-hour clock in the
Hour:
field and press
Tab
to move to the next field.
7. Type the current minute (0 through 59) in the
Minute:
field (seconds
cannot be set). When done, press
Tab to move to next field
8. Type
standard
or
daylight savings
in the
Type
field, according to the
current time in the local time zone. For example, if currently on standard
time, type
standard
.
9. Type the rule number in the
Daylight Savings Rule
field.
10. When all the information is correct, press
Enter.
11. Type
display time
and press
Enter to verify date and time data.
Set Core Dump Vector
1. Type
set vector f spe-maint
and press Enter to set the core dump vector to
perform a core dump on any system restart.
Enable TTI
NOTE:
Do this step only if the TTI is disabled and you want it enabled.
1. Type
change system-parameters features
and press
Enter to change the
TTI field back to its value before the upgrade.
Table 1-4. English Month Names
Number Name Number Name
1 January 7 July
2February8August
3 March 9 September
4 April 10 October
5 May 11 November
6 June 12 December