Lucent Technologies 555-233-115 Server User Manual


 
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Fiber Link Administration
A-6Administer Fiber Links
A
d. The
DS1CONV Board Type
: field is display only and shows the
type of DS1 Converter circuit pack in Endpoint-1. The circuit pack
type in Endpoint-1 (A-PNC) and Endpoint-1 (B-PNC) must match.
e. In the
Is one endpoint remoted via a DS1 Converter
Complex?
field, type
y
to specify that a DS1 Converter complex is
used to remote 1 endpoint. If
y
is entered, administer the A-PNC
DS1 Converter Board Location on Page 1. The A-PNC DS1
Converter Board Type displays.
7. On Page 2 of the form:
a. Administer the A-PNC DS1 Converter (DS1CONV) Attributes.
b. Enter the DS1 Converter Facilities information. In the
Facility
Installed?
field, type
y
for all installed facilities (A, B, C, and D).
c. In the
Bit Rate
: field, type
1.544
for T1 operation or
2.048
for E1
operation.
NOTE:
One bit rate applies for all facilities within the same DS1
Converter complex. The
Bit Rate:
field displays only under
Facility A.
d. Enter the idle code in the
Idle Code MSB (1) . . . . LSB
(8):
field. The default value is
11101000
. It is recommended that
the default value be used unless it becomes absolutely necessary
to change it. The “MSB” means Most Significant Bit, the “LSB”
means Least Significant Bit.
e. Enter the appropriate data in the
Line Coding:
field. This data
should match the line coding of the facility. For T1, example line
coding is
b8zs
. For E1, example line coding is
hdb3
.
f. Scroll to Page 3 and modify the fields as needed for the B-PNC.
NOTE:
If this data is not correct, wideband errors (such as
multimedia call handling) may occur.
8. For T1 sites, refer to ‘‘T1 Installations Only’’
. For E1 sites, refer to ‘‘E1
Installations Only’’.