Lucent Technologies 555-233-115 Server User Manual


 
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Adding or Removing Cabinet Hardware
6-126Add Center Stage Switch
6
Figure 6-47. 3-SN CSS with High Inter-SN Traffic
Fiber Engineering for 3 SNs
Switches with 3 SNs are connected by 1 to 7 fiber links to provide sufficient
switching fabric at the CSS. The traffic in all locales within a single SN does not
require engineering. Only traffic that links from locales in 1 SN to another SN (and
vice versa) must be engineered. The traffic that links across these fibers is simply
the sum of the traffic that links to locales located in the other SN.
Figure Notes
1. Switch Node (SN) 1
2. Switch Node 2
3. Switch Node 3
4. PPN Cabinet
5. EPN Cabinet 1
6. EPN Cabinet 9
7. Inter-SN Connections (3 fibers)
8. EPN Cabinet 10
9. EPN Cabinet 20
10. Inter-SN Connection (2 fibers)
11. EPN Cabinet 21
12. EPN Cabinet 31
cydfpbx2RPY 081897
1
2 3
4 5 6
7 7
89
10
1112