Lucent Technologies 555-233-115 Server User Manual


 
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Adding or Removing Cabinet Hardware
6-132Add MCC Port Carriers
6
Power Up MCC Port Network
1. At the MCC port network, set the main circuit breaker to ON.
2. The system performs a level 4 rebooting process, loading the system
program and default translations from the disk. Rebooting takes 5 to 11
minutes.
3. Refer to “Initialization and Recovery” and “LED Interpretation” chapters in
DEFINITY Enterprise Communications Server Release 8 Maintenance for
R8r
, for circuit pack LED indications and management terminal displays
that occur during system reboot.
4. After the system reboot is finished and all trouble cleared, verify that the
EMERGENCY TRANSFER CONTROL switch is set to AUTO. This restores
the system to the normal operating mode.
Restart DEFINITY LAN Gateway System
1. Log onto the DEFINITY LAN Gateway.
2. When the main menu appears, select
Maintenance
.
3. Select
Reset System
from the
Maintenance
menu.
4. Select
Restart System
from the
Reset System
menu.
Enter Added Translations
1. Enter added translation data as applicable using
DEFINITY Enterprise
Communications Server Release 8 Administrator’s Guide
.
Resolve Alarms and Enable Alarm Origination
1. Examine the alarm log. Resolve any alarms using
DEFINITY Enterprise
Communications Server Release 8 Maintenance for R8r
.
2. If the
Alarm Origination Activated
field administration is already
set to
y
, be sure to enable Alarm Origination. Otherwise you do not need to
enable Alarm Origination (proceed to the next section).
3. Type
change system-parameters maintenance
and press
Enter.
The
Alarm Origination Activated
field was changed to
Alarm
Origination to OSS Numbers
to support more than 1 OSS.