Lucent Technologies 555-233-115 Server User Manual


 
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN
5-77Critical Reliability
5
Check Link Status
1. Type
display communication-interface links
and press Enter. Write down
all enabled links.
2. Type
status link
number
and press Enter. Repeat this step for all links.
3. Write down which links are in service.
Disable TTI
!
CAUTION:
If you do not disable the TTI, the translations can be corrupted.
1. Make sure the ISDN is in service. If not, attempt to busy out and release
the ISDN D-channel/link. This will bring the ISDN trunks back into service.
2. Type
change system-parameters features
and press
Enter.
3. On the second screen, set the
Enabled?
field to
n
to prevent the TTI
feature from activating.
Power Down G2 System
At the power distribution unit, set the main circuit breaker to OFF.
Install Power-Failure Transfer Ground Wire
!
CAUTION:
To avoid contaminating single-point ground, do not connect the ground wire
while the system is powered up.
1. Connect 1 end of a 10 AWG (#25) (2.6 mm
2
) wire either to pin 49 of the
connecting block or to pin 49 of the CAP (cable access panel) associated
with the power-failure transfer panel.
2. Route the opposite end of the wire to an approved ground source and
connect.