Lucent Technologies 555-233-115 Server User Manual


 
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN
5-44High Reliability
5
High Reliability
Required Hardware
The equipment in Table 5-10 must be on-site before the upgrade begins. To
place a claim for missing equipment, as part of the Streamlined Implementation
process, call 1-800-772-5409, or the number provided by your Lucent
Technologies representative.
Table 5-10. Required Hardware
Equipment Description Quantity
J58890A
(PEC 6300-05X)
Processor Port Network 1
J58890AF Expansion Control Carrier 1
106647985 TN775B Maintenance 1
103557294
or
103281788
TN776 Expansion Interface
TN570 Expansion Interface
2 or 6
1
2 or 6
1,2
1. Use 2 for a high reliability system with 2 port networks; 6 with 3 port networks. Either 1
or 4 Expansion Interfaces (EIs) ship loose with the EPN equipment. The factory has
installed either 1 or 2 EIs in the new PPN.
2. Required port network interfaces in a Release 8 system with the optional packet bus.
J58890TO-1 L1 Removable Media 4
407439975 20-Foot Multi-mode Fiber Optic Cable 1 or 3
3
3. Use 2 or 6 if the PPN and EPN(s) are remotely located. The fiber that previously
connected an upgraded G2 universal module (not a traditional module) to the G2 TMS
has the correct transceiver connectors and, therefore, can be reused.
106455348
or
106455363
9823-A Lightwave Transceiver
9823-B Lightwave Transceiver
2 or 6
4
2 or 6
5
4. One pair for each fiber connection. For each connection, install one 9823-type
lightwave transceiver in an EPN and 1 in the PPN. A 9823-type transceiver can be
reused from each upgraded G2 universal module. Additional transceivers also ship
loose with the EPN equipment.