Adding or Removing Cabinet Hardware
6-76Add IP Interface Assembly
6
Upgrade to TN802B (R8)
NOTE:
The upgrade takes about 20 minutes.
1. Insert the flash disk into the right most slot on the TN802 IP trunk. On the
monitor, a dialog box assigns a drive letter with the removable media
designation; the default is D:.
2. Right click on
Start > Explore
to open the Windows NT Exploring pane
and select the drive letter indicated in step 1.
3. Double-click on
Medpro
and select the Setup icon.
4. Follow the Install Shield procedure to transfer all the necessary files to the
TN802 IP Interface.
NOTE:
In the Finish dialog box, select
I will restart later
. Do not
select
Restart computer
.
This would be a good time to read the Readme.txt file.
5. Click on
Start > Settings > Control Panel > Services
.
6. Select
IP Trunk
and click on
Startup
.
NOTE:
Do not click on Start.
7. Under Startup Type, select
Disabled
and click
OK
to disable IP Trunk
mode.
NOTE:
If IP trunk and MedPro services are both set to automatic, the
TN802B defaults to IP Trunk and MedPro features cannot be used.
8. Select
MedPro
and click on
Startup
.
NOTE:
Do not click on Start.
9. Under Startup Type, select
Automatic
and click
OK
to enable MedPro
mode.