Lucent Technologies 555-233-115 Server User Manual


 
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Fiber Link Administration
A-16Administer Fiber Links
A
Duplicated DS1C Converter Complex Administration
for TN574 Circuit Packs.
Screen 6-4. Fiber Link Administration form for TN574 Circuit Pack (Duplicated DS1
Converter Complex Administration) (page 3 of 3)
Page 3 appears when the Is one endpoint remoted via a DS1 Converter Complex
field is "
yes
" and duplication is enabled.
NOTE:
When you administer DS1 Converter TN1654 circuit packs, different fields
display.
For field definitions of the fields displayed on page 3 of the Fiber Link
Administration form, refer back to the previous section.
add fiber-link next Page 3 of 3
FIBER LINK ADMINISTRATION
B-PNC DS1 CONVERTER (DS1CONV) ATTRIBUTES
DS1CONV Board Location: 01C01 DS1CONV Board Location: 02C01
DS1CONV Board Type: TN574 DS1CONV Board Type: TN574
DS1 CONVERTER FACILITIES
ABC D
Facility Installed? yes no no no
Passes Far-end Clock? yes yes yes yes
Digital Data Compatible? yes yes yes yes
Line Coding: ami-zcs ami-zcs ami-zcs ami-zcs
Framing Mode: esf esf esf esf
DS1CONV-1 Line Compensation: 1 1 1 1
DS1CONV-2 Line Compensation: 1 1 1 1
Facility B Circuit ID: 01112343