Lucent Technologies 555-233-115 Server User Manual


 
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN
5-40Standard Reliability
5
Set Additional Administration
1. Type
list configuration software-version
and press Enter to compare the
version number of the Release 8 software program (displayed on the
terminal) with the TN786B version number (written on a label on the
TN786B’s faceplate). If the version numbers are not the same, change the
version number on the TN786B label so that they agree.
2. Type
change system-parameters customer-options
and press
Enter.
Use this screen to enable the customer’s right-to-use options on the
upgrade order. See
DEFINITY Enterprise Communications Server Release
8 Administrator’s Guide
, for details.
3. Type
change site-data
and press
Enter. Use this screen to assign
system-specific information (such as building, floor, stations, and so
forth).
4. Type
save translation
and press
Enter. This instructs the system to write all
translation information from memory to the translation card.
!
CAUTION:
If the terminal screen displays “translation corruption detected; call
Lucent Technologies distributor immediately”, an error was detected
in the translations. Call your Lucent Technologies representative.
Reconnect Cables to Upgraded EPN Cabinet
1. At the power distribution unit of the upgraded EPN, set the main circuit
breaker to OFF.
NOTE:
Powering down an EPN without powering down the PPN will set off
alarms. However, these alarms should clear after power is restored
to each EPN.
2. Temporarily disconnect the lightwave transceivers and fiber optic cables
from the appropriate carriers.
3. Replace the rear doors or rear panels previously removed.
4. At the EPN cabinet, reconnect the lightwave transceivers, fiber optic
cables, and the connector cables.
5. Install the front door on the EPN cabinet if previously removed.