Multicarrier G2 Universal Module to R8r EPN
5-75Critical Reliability
5
Critical Reliability
Upgrade Cabinets
An existing universal module cabinet is always upgraded to an EPN.
Required Hardware
The equipment in Table 5-14
must
be on-site before the upgrade begins. To
place a claim for missing equipment, as part of the Streamlined Implementation
process, call “1-800-772-5409” or the number provided by your Lucent
Technologies representative.
Table 5-14. Required Hardware
Equipment Description Quantity
PEC 6300-05X Processor Port Network 1
J58890AF Expansion Control Carrier 1
J58890BB-3 Port Carrier 1
106647985 TN775B Maintenance 1
103557294
or
103281788
TN776 Expansion Interface
TN570 Expansion Interface
4 or 12
1
4 or 12
1
,
2
1. Use 4 for a critical reliability system with 2 port networks or 12 with 3 port networks.
Either 2 or 8 Expansion Interfaces (EIs) ship loose with the EPN equipment. The factory
has installed the other 2 or 4 EIs in the new PPN.
2. Required port network interfaces in a Release 8 system with the optional packet bus.
J58890TO-1 L1 Removable Media 4
H-600-204 G1 ICC 2
3
3. Required for an EPN in a critical reliability system.
407439975 20-Foot Multi-mode Fiber Optic Cable 2 or 6
4
4. Use 4 or 12 if the EPNs and the PPN are remotely located. Assuming acceptable
lengths, the fibers previously connecting an upgraded G2 universal module (not a
traditional module) to the G2 TMS have the correct transceiver connectors and can be
reused.
106455348
or
106455363
9823-A Lightwave Transceiver
9823-B Lightwave Transceiver
4 or 12 (See Note 1)
4 or 12 (See Note 1)
106689516 TN771D Maintenance Test 1 or 2