Lucent Technologies 555-233-115 Server User Manual


 
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Adding or Removing Cabinet Hardware
6-44Add DCS Interface
6
Enter Added Translations
1. Get the DOSS order number of the upgrade. Call the regional CSA to
perform the steps in this section.
2. To enable DCS, set the
DCS
field on the System Parameters-Customer
Options screen to
y
.
3. Administer the other required translation data using the forms listed under
Distributed Communications System (DCS) in
DEFINITY Communications
System Administration for Network Connectivity
.
Save Translations
1. If the system is high- or critical-reliability, type
status spe
and press Enter
to verify that the standby SPE is refreshed and that the standby disk is in
service.
2. Enter
save translation [spe-a or both] disk
and press
Enter. This
command instructs the system to take all translation information in
memory and write it to the disk(s).
Table 6-3. TN799 Pinout
Backplane Pin 25-Pair Wire Color Lead Name
Peripheral
Connector Pin
103 White/Orange TD+ 27
003 Orange/White TD- 2
104 White/Green RD+ 28
004 Green/White RD- 3