DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Upgrading G3rV2, V3, V4 to R8r and Adding Memory
1-7Upgrade the software and hardware
1
Disable Scheduled Maintenance and Alarm
Origination to INADS
1. To prevent scheduled daily maintenance from interfering with the update
or upgrade, type
change system-parameters maintenance
and press
Enter.
2. If scheduled maintenance has begun, set the
Stop Time
field to 1 minute
after the current time.
or
If scheduled maintenance has
not
begun, set the
Start Time
field to a
time after the upgrade is completed. For example, if you start the upgrade
at 8:00 p.m. and the upgrade takes 90 minutes, set the
Start Time
field
to 21:30.
!
CAUTION:
If you do not disable Alarm Origination, the system may generate
alarms, resulting in unnecessary trouble tickets.
3. Type
neither
in the
Alarm Origination to OSS Numbers
field and
press
Enter.
NOTE:
For some software loads, set the
Alarm Origination
Activated
field to
n
and
set the
Cleared Alarm Notification
and
Restart Notification
fields to
disable
or
n
before
pressing
Enter.
Reconfigure the Tape (G3rV2, V3 R31.0 and
Earlier)
NOTE:
Do not issue the
list configuration software
command before
reconfiguring the removable media.
For some software loads, use
3-mem
instead of
large
If standard reliability:
1. Type
configure tape large
and press
Enter to reconfigure the backup
removable media for the 2 TN1650B Memory circuit packs. This command
takes about 1 minute to complete.