4 - 76 ONline Ethernet Bridge Module Installation and Operation Guide
SET TERMINAL BAUD
Use the SET TERMINAL BAUD command to establish the appropriate baud
rate at which the Bridge Module receives and transmits data to your
terminal or modem.
Format
SET TERMINAL BAUD {baud rate}
Parameters
{baud rate} = 300, 1200, 2400, 4800, or 9600 (default is 9600)
Example
This example changes the baud rate to 4800 baud.
OEBM> set terminal baud 4800 [ENTER]
Terminal parameter changed
Description
The SET TERMINAL BAUD command enables you to establish the
appropriate baud rate at which the Bridge Module receives and transmits
data to your terminal or modem.
Check the baud rate of the device before connecting a terminal or modem
to the Bridge Module. Your device and the Bridge Module must be set at
the same baud rate in order to communicate.
If you need to set the Bridge Module to communicate with a device that
has a baud rate lower than 9600 baud, use the following procedure:
1. Connect a terminal (set to 9600 baud) to the Bridge Module (via the
RS-232 front panel serial port) and log on to the bridge.