4 - 108 ONline Ethernet Bridge Module Installation and Operation Guide
SHOW LAST_ERROR
Use the SHOW LAST_ERROR command to display information on the last
fatal error that occurred at the local bridge.
Format
SHOW LAST_ERROR
Parameters
none
Example
OEBM> show last_error [ENTER]
Display of Last Error - Flash Version: v2.00
Crash reason: Address Error
-0- -1- -2- -3- -4- -5- -6-
A=0047D35E 004773E4 00402D04 00000000 00000000 00000000 0047D3C4
D=00000001 00200000 000000FF 00000009 00000000 00000000 00000000
PC = 014B30 SR = 2000
Stack Dump
47D308 4E 76 00 00 00 01 4E 75 - 20 00 00 01 4B 30 00 00.Nv.Nu..K0.
47D318 00 00 00 00 00 00 00 00 - 0B B8 00 47 D3 5E 00 00.Copyright.
47D328 00 00 00 00 00 00 00 00 - 00 00 00 01 00 00 00 00.3Com...
47D338 00 00 00 FF 00 00 00 00 - 00 00 00 00 00 00 00 00.Corporatio
47D348 00 00 00 66 00 00 0A 20 - 63 6F 70 79 72 69 67 61.n.1991....
47D358 74 20 31 39 39 31 20 43 - 68 69 70 63 6F 6D 20 43.ONline....
47D368 6F 72 70 6F 72 61 74 69 - 6F 6E oA 20 4F 4E 6C 69...Bridge..
47D378 6E 65 20 42 72 69 64 67 - 65 20 4D 6F 64 75 6C 65...module..
Description
The SHOW LAST_ERROR command displays information on the last fatal
error that occurred. This information may indicate a problem with the
Bridge Module. Log the error information and track the problem. If you
receive fatal errors frequently, call 3Com Technical Support as outlined in
the Technical Assistance section at the end of Chapter 5.