3Com 5102B-EE Network Router User Manual


 
D - 4 ONline Ethernet Bridge Module Installation and Operation Guide
followed by a left parentheses. These messages start about halfway
through the self-test after preliminary functionality is verified.
For example, when the LANCE 802.3 port test starts, the following appears
on the screen:
lance_1(
When the routine is completed successfully, a right parentheses appears,
followed by the next routine. For example, when the LANCE routine is
completed and the LANCEMEDIA routine begins, the screen display is as
follows:
lance_1 (0123)
lancemedia_1(
When the entire self-test routine is completed, the Bridge Module
identification header is displayed.
When an error occurs, additional information may appear on the screen
depending on the routine running at the time. Be sure you record this
information before calling Customer Support, as described below.
When an Error Occurs
If an error occurs during the Bridge Module self-test, follow these steps:
1. Record the following information:
Diagnostic Code and Subtest Code (all LED values)
Screen display information (if available)
Bridge Module serial number and Ethernet address
Date and time
2. Refer to Chapter 5, Troubleshooting, for information on diagnosing
error conditions.