3 - 12 ONline Ethernet Bridge Module Installation and Operation Guide
Note: Terminal values you set using the SET command are not
saved permanently until you issue the SAVE TERMINAL
command. Once the values are saved, if you log out or
even if the power fails, the saved values are retained.
Automatic Modem Hangup
If you use a modem to connect to the Bridge Module, you may want to use
the SET TERMINAL HANGUP command to hang up the modem connection
automatically when you log out of the Bridge Module. The factory default
is disable, which does not automatically hang up a modem. The following
example shows the command used to automatically hang up the modem
once you log out of the Bridge Module.
OEBM> set terminal hangup enable [ENTER]
Note: If you fail to hang up the modem connection, an
unauthorized user may pick up the last login session.
Configuring the Bridge Module
Now that the terminal settings are complete, you can configure the Bridge
Module in the concentrator. We recommend that you complete the
following steps when you log in for the first time:
1. Establish passwords
2. Configure other Bridge Module parameters
3. Set Bridge Module SNMP values
Establishing Passwords
Bridge Management provides a password-protection capability that allows
you to control access to certain commands and information. You must be
in administrator mode to be able to change passwords. Note that when
you first log in the default password is [ENTER]. This default password will
provide you with administrator privileges.