3 - 6 ONline Ethernet Bridge Module Installation and Operation Guide
Modifying Parameters
Parameter values are stored in non-volatile memory on the Bridge Module.
Your Bridge Module unit is shipped from the factory with specific default
parameter values. Some of the default parameter settings are shown on
the previous page in the example explaining the SHOW DEVICE command.
Use the SET command to modify parameter values. You must first type the
administrator password when you log in to the management interface. The
administrator password provides access to commands that allow you to
modify the current bridge configuration.
Once you have entered the administrator password, you can change
parameter values using the SET command. Listed below is an example of
changing the Bridge Module terminal baud rate.
OEBM> set terminal baud 1200 [ENTER]
Terminal parameter changed
Once you have made all the parameter changes you want, you may want
to issue the SAVE ALL command and then logout of administrator mode to
prevent any unauthorized changes.
Saving Parameters
When you reboot the system, all parameters that can be set are reset to
their saved values. Therefore, to save the new parameter values you
changed and make them effective on the next reboot, you must issue the
SAVE command before rebooting. Use the SAVE command to save
parameter values for the following groups:
All
Alert
Bridge
Community
Device