2 - 16
Chapter 2 Operation of Diag.
4.2.3 Exiting digital input (DI) test
1) Press “CANCEL” key to stop the DI Test.
2) Press “MENU” key to exit the DI Test mode. (“IOT Diag” and “Digital Input” are displayed
after that “Please Wait” was displayed.)
3) Press “CANCEL” key, “IOT Diag” is displayed.
To shift the mode from Diag. mode to the normal mode, perform as follows.
4) Press “ ” key to select “Complete”.
5) Press “ 3 ” key three times to exit the “Diag. Mode.”
4.2.4 How to check sensors and switches
- Parts Location
Ten02001KA
No Toner Sensor K
[DI-1B]
Toner Cartridge Sensor M
[DI-9]
Toner Cartridge Sensor C
[DI-a]
Toner Cartridge Sensor K
[DI-b]
Toner Cartridge Sensor Y
[DI-8]
No Toner Sensor Y
[DI-18]
No Toner Sensor M
[DI-19]
No Toner Sensor C
[DI-1A]
Cassette 1 Size
[DI-38]
Tray 1 No Paper
[DI-11]
Refer to 4.2.1
Refer to 4.2.1
Refer to 4.2.1
Refer to 4.2.1
Refer to 4.2.1
Refer to 4.2.1
Interlock Open
[DI-7]
DUP Jam Sensor
[DI-1]
REGI Sensor
[DI-3]
BTR Toner Full
[DI-23]
MSI No Paper
[DI-10]
Exit Sensor
[DI-2]
Full Stack Sensor
[DI-0]