Chapter 2 Operation of Diag.
Interlock Open (DI-7)
1) Turn on the power and enter the Diagnostic Mode.
2) Execute the DI-7.
3) Push the Side Button to open and close the Front Cover.
Check the number on the control panel is counted up.
4) Close the Front Cover.
5) Press the “CANCEL” key to stop the test.
Toner Cartridge Sensor Y
(DI-8)
1) Turn on the power and enter the Diagnostic Mode.
2) Remove the Top Cover.
3) Execute the DI-8.
4) Move the levers on both ends of the Yellow Toner backward to
release the lock.
Check the number on the control panel is counted up.
5) Press the “CANCEL” key to stop the test.
6) Rotate the levers of the Yellow Toner forward until it locks
firmly. (You may hear a click when the Toner Cartridge seats
properly.)
7) Reseat the Top Cover.
Sensor name (Diag. Code) Confirmation procedures