Chapter 3 Removal and Replacement Procedures (RRPs)
RRP7.2 CRUM (PL7.1.4)
[Removal]
1) Release the latch and open INNER DUPLEX ASSEMBLY (PL5.2.1).
2) Open the hook that fix CRUM to the upper left section of DEVELOPER FRAME, remove the
CRUM.
3) Remove the connector (P/J710) from the CRUM, remove the CRUM.
[Replacement]
1) Attach the connector (P/J710) to the CRUM.
2) Attach CRUM on DEVELOPER FRAME by fixing with hook located at the upper left section
of DEVELOPER FRAME.
3) Close INNER DUPLEX ASSEMBLY.