2 - 45
Chapter 2 Operation of Diag.
Fuser Motor (Full 1 Forward)
(DO-1f)
Fuser Motor (Full 2 Forward)
(DO-20)
Fuser Motor (Half Forward)
(DO-21)
Fuser Motor (Slow Forward)
(DO-22)
NOTE: The following procedures are for the technical staff. The
customer check is procedures 1, 4 and 5.
1) Turn on the power and enter the Diagnostic Mode.
2) Push up the Front Latch to open the Front Cover.
3) Cheat the safety Interlock System.
4) Execute the DO-1f, DO-20, DO-21 or DO-22. Confirm the
rotation of the motor. (The customer can confirm the motor
noise only.)
The rotational speed of the motor is as follows.
DO-22 (slow speed) < DO-21 < DO-20 < DO-1f (high speed)
5) Press the “CANCEL” key to stop the test.
6) Remove the cheater.
7) Close the Front Cover.
Motor, Clutch and Solenoid
name (Diag. Code)
Confirmation procedures
Ida_Sec02_035F
A
2)-1
2)-2
Fuser Motor