2 - 53
Chapter 2 Operation of Diag.
MSI Feed Solenoid (DO-54)
1) Turn on the power and enter the Diagnostic Mode.
2) Execute the DO-54. Upon pressing the “ 3 ” key, confirm the
operation noise of the solenoid is heard.
3) Press the “CANCEL” key to stop the test.
Combination test is as follows.
NOTE: The Multipurpose Feeder (MPF) Separator Roller rotates
when the DO-0 and DO-54 are executed. The following procedures
are for the technical staff.
1) Open the Multipurpose Feeder (MPF) Tray.
2) Turn on the power and enter the Diagnostic Mode.
3) Execute the DO-0 and DO-54. Confirm the rotation of the
Multipurpose Feeder (MPF) Separator Roller.
4) Press the “CANCEL” key to stop the MSI Feed Solenoid test
(DO-54 test).
5) Press the “ ” key to display the DO-0.
6) Press the “CANCEL” key to stop the Main Motor (DO-0 test).
7) Close the Multipurpose Feeder (MPF) Tray.
Motor, Clutch and Solenoid
name (Diag. Code)
Confirmation procedures
Ida_Sec02_044FA
Multipurpose Feeder (MPF) Roller
Multipurpose Feeder (MPF) Separator Roller
1)