Ricoh AP2610N Printer User Manual


 
Appendix
100
7
Configuring the IPP user authorization
Use the following command:
ipp user
The following message appears.
Input user number (1 to 10):
Type the number, user name and password.
IPP user name:user1
IPP password:*******
After configuring the settings, the following message appears.
User configuration changed.
Direct Printing Port
The direct printing port allows printing directly from a computer, connected to
the network, to the printer.
Use the diprint command to change the direct printing port settings.
View settings
The following command displays the current direct printing port settings.
msh> diprint
Example output:
port 9100
timeout=300(sec)
bidirect off
The Port specifies the port number of the direct printing port.
The bidirect setting indicates whether the direct printing port is bidirec-
tional.
Setting timeout
You can specify the timeout interval to use when receiving data from the net-
work.
msh> diprint [0~65535]
Note
The factory default is 300 seconds.
If 0 is set, timeout is disabled.
Bidirectional configuration for the direct printing port
Use this setting to configure whether the direct printing port is bidirectional.
The factory default is off.
msh> diprint bidirect {on|off}
Note
If you select on, SmartNetMonitor for Client or Standard TCP/IP on
Windows 2000 might not work correctly.